CPS®-3000: 3000kW Utility-Scale Energy Storage Inverter


Download the CPS-500 datasheet by entering your info below

GEN 4: LOWER COST. BETTER PERFORMANCE UTILITY-SCALE ENERGY STORAGE INVERTER

Theis CPS®-3000 is a cost-effective, reliable, and efficient utility-scale energy storage inverters offered in both indoor and outdoor configurations. Featuring a highly-efficient three-level topology, Dynapower’s CPS® inverters are air-cooled and designed for four-quadrant energy storage applications in both grid-tied and microgrid applications. Multiple CPS® units can be paralleled together to scale to meet the needs of any energy storage installation.

Dynapower can supply from standalone CPS® inverter system to complete fully-integrated energy storage solutions. CPS® inverters can be supplied with MV transformers to easily integrate customer supplied battery systems into any network. Alternatively, Dynapower can supply a fully-integrated solution with it’s CPS®-i platform. Outdoor rated CPS® inverters are enclosed in a NEMA 3R containers that can be moved with a forklift and allow for placement on gravel or concrete pylons, creating installation savings.

INTEGRATED FEATURES

  • AC Breaker With Shunt Trip
  • DC Disconnect
  • DC Input Fuses
  • Forced Air Cooling System

WHY DYNAPOWER

+ BANKABLE — > 50,000 POWER CONVERSION UNITS DEPLOYED SINCE 1963

+ PROVEN — OVER 500MWs OF ENERGY STORAGE COMMISSIONED WORLDWIDE

+ RELIABLE — UNSURPASSED UPTIME

+ COST EFFECTIVE — INDUSTRY-LEADING ROI

+ 24/7 SUPPORT — TECH SUPPORT & FIELD SERVICE WORLDWIDE

WHO WORKS WITH US

Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
Logo Image
{"slides_column":"3","slides_scroll":"1","dots":"false","arrows":"true","autoplay":"true","autoplay_interval":"3000","ticker":"false","speed":"600","center_mode":"false","loop":"true","rtl":"false"}

KEY CPS® TECHNOLOGIES

BLACK START — In the event of a complete system power outage, Dynapower’s patented Black Start restores power to the facility without the need for external power. Dynapower’s Black Start technology can start distribution networks even with transformer magnetizing currents that exceed the power rating of the inverters. Multiple CPS® units can be restarted at once.

E COMP— A Volt Var function that provides immediate and automatic voltage support to the grid.

F COMP— A Hz-Watt function that provides immediate and automatic frequency support to the grid.

DYNAMIC TRANSFER™ — Dynapower’s proprietary patented Dynamic Transfer algorithm monitors grid stability and, upon detecting a grid disturbance, disconnects from the grid and transitions to stand-alone battery backup power mode on the load connection. The transition is seamless to the critical loads and supports 100% phase imbalance in UF mode.


Download the Dynamic Transfer Functional Overview by entering your info below 

TWO MODES OF OPERATION

The CPS®-3000 provides two modes of operation — Grid-Tied (PQ-mode) and Stand-Alone (UF mode). In the Grid-Tied mode, the patent-pending CPS®-3000 controls the AC output real power (P) and reactive power (Q). In Stand-Alone mode, it controls the AC output voltage (U) and frequency (F). The system can be started in either mode and the transfer between modes is done dynamically. Advanced controls schemes for multi-unit and microgrid applications are available.

SYSTEM CONTROL

Dynapower’s state of the art control and monitoring platform provides operators with both local and remote operation of the system. In the remote operating mode, a communication link provides autonomous operator control via Ethernet. For local control, Dynapower can provide an Operator Interface Terminal (OIT) for error set commands and full system display status.

COMPREHENSIVE SYSTEM MONITORING

The patent-pending CPS®-3000 provides full system status information including AC output real & reactive power, AC output voltage & frequency and DC battery voltage and DC current readings to the remote operator through feedback signals or through the communication link (via an RTU or PLC). It has an onboard monitoring system with error history and grid fault data capture. System operating information is displayed on the OIT in both local and remote modes of operation.

COMMON CPS APPLICATIONS

CAPACITY RESERVE
Provide power and energy capacity to the grid as a standalone asset.

RENEWABLES INTEGRATION
Smooth and firm the output of a renewable power generation source such as wind or solar.

MICROGRIDS
Build a localized grid where no utility grid is available or disconnect from the main power grid operating independently in the event of an emergency.

ANCILLARY SERVICES
Charge or discharge instantly to provide frequency regulation, voltage control, and spinning reserve services to the utility grid.

TRANSMISSION & DISTRIBUTION
Supply power and energy capacity at a distributed location to defer or eliminate the need to upgrade aging grid infrastructure.

CPS®-3000 SPECIFICATIONS

DC Voltage
740-1500 VDC
Max DC Current
4,000A
DC Voltage Ripple
<1%
DC Inputs
2 isolated inputs

 

Works with all battery chemistries and with a floating configuration.

AC Line Voltage
480 – 600 VAC 3 Phase
AC Line Frequency
60 Hz
Continuous AC Current
2,888 A RMS
Overload AC Current
3,458 A RMS
Continuous AC Power
2,400 kW (@480) 3,000 kW (@600)
Power Factor
0 – 1.0 Leading or Lagging
Current Harmonics
IEEE 1547 Compliant, <5% TDD
Peak Efficiency
98.5% CEC

Operating Temp
-25 to 60°C, De-rated above 45°C
Cooling
Forced Air Cooled
Enclosure
NEMA 1/IP 20 (Indoor), NEMA 3R/IP 54 (Outdoor)
Dimensions (HxWxD)
81” x 110” x 33” or 81” x 55” x 66” (Two Indoor Configurations)
102” x 96” x 118” (Outdoor)
Weight
8,000 lbs (Indoor)
14,000 lbs (Outdoor)
Storage Temperature
-40°C to 65°C

FAULTS
AC Over Voltage, AC Under Voltage, AC Under Frequency, AC Over Frequency, AC Overload, Over-temperature, DC Over Voltage, DC Over Current

STANDARDS COMPLIANCE
IEEE 1547, UL 1741 SA

SAFETY FEATURES
Anti-islanding with UL Compliant trip points, Hardware Over Current Protection, Surge Protection

CONTACT US

To learn more about Dynapower solutions or to discuss a project please call (802) 860-7200 or Request a Quote here.